Battery-pH meter Portamess® 910 Portable pH meters of the Portamess® 910 pH series. Providing the function abundance of high-quality benchtop meters with easy, pictograph-guided operation. Compact construction. Comfortable handling. Water-proof enclosure, specially developed for field applications. Appealing design. Extremely flat. Constructed for a firm grip. For many different applications such as in industry, for environmental protection, food processing, and water and waste-water measurements.
Battery pH Meters Portamess® 910 pH
Portamess®911 pH - the basic model |
Measurement ranges: |
pH: | -2,00 to +16,00 |
mV: | -1300 to +1300 |
°C: | -20,0 to +120°C |
Meas. error (± 1 digit): |
pH: | <0,01 |
mV: | <0,1% v. M. ±0,3 mV |
°C: | <0,3 K |
Electrode adaptation: | Calimatic® automatically recognizes the right buffer, for automatic calibration; (DBP 29 37 227) 8 buffer sets to choose from |
Temperature compensation: | Pt 1000 / NTC 30 kΩ (automatic recognition at switch-on, or manually) |
EMC directive: | 89/336/EEC |
Standards: | EN 61326 / VDE 0843 Part 20:2002-3 |
Case: | Material PA, protection type IP 66, with integrated electrode quiver |
Operating time: | 2000 h with 3 AA batteries |
Dimensions: | 133 × 160 × 30 mm (W × H × D) |
Weight: | approx. 560 g with batteries |
Portamess®913 pH - Equipped for digital communication |
Same as 911 pH, plus: |
Time function: | integrated real-time clock with date |
Measurement memory: | 100 memory slots: pH/mV,°C, time and date |
Electrode adaptation: | manual calibration with any 2 buffers also possible |
Interface: | serial, bidirectional, synchronous, 4800 Baud, configurable as printer or computer interface |
Data logger: | manual, controlled by interval or event |
Interface cable: | 1m long, universal plug, for connecting either to a PC or printer |
| Article | Order No. | |
| Battery pH meter Portamess 911 pH | 61 60 91101 | |
| incl. batteries, electrode quiver and carrying strap, without electrode | |
| Battery pH meter Portamess 913 pH | 61 60 91301 | |
| same equipment as 911 pH; plus clock and measurement memory, incl. batteries, electrode quiver and carrying strap, data logger and interface, incl. Paraly® transfer software and interface cable, without electrode. | |
Accessories
| Article | Order No. | |
| Calibration buffer set ZU 0261 | 61 60 97261 | |
| with Knick technical buffer solutions pH 4, 7, 9 and KCl, 250 ml of each | |
| Buffer pH 4 (set/30 bags) ZU 0263 | 61 60 97263 | |
| pH 4 (set of 30 bags for one-time calibration) | |
| Buffer pH 7 (set/30 bags) ZU 0264 | 61 60 97264 | |
| pH 7 (set of 30 bags for one-time calibration) | |
| Buffer pH 9 (set/30 bags) ZU 0265 | 61 60 97265 | |
| pH 9 (set of 30 bags for one-time calibration) | |
| KCI solution (250 ml bottle) ZU 0062 | 61 60 97062 | |
| Measuring probe, pH/Pt 1000 combination electrode SE 101 N | 61 60 97101 | |
| plastic with integrated Pt 1000 temp. sensor, pH 0 to 14, 0 to 80°C | |
| Measuring probe, pH/Pt combination electrode/glass SE 102 N | 61 60 97102 | |
| Measuring probe, pH insertion combination electrode/plastic SE 104 N | 61 60 97104 | |
| Pt-1000 temperature probe ZU 0156 | 61 60 97156 | |
| Electrode quiver ZU 0262 | 61 60 97262 | |
| (5 quivers; for storing pH electrodes safe from liquids) | |
| Robust field case ZU 0277 | 61 60 97277 | |
| for instrument and electrode | |
| Laboratory printer ZU 0244 | 61 60 97244 | |
| Printing paper ZU 0249 | 61 60 97249 | |
| for ZU 0244 laboratory printer (5 rolls) | |
| Color ribbon ZU 0250 | 61 60 97250 | |
| for ZU 0244 laboratory printer (5 pcs) | |
pH sets
| Article | Order No. | |
| pH set A, ZU 0510 | 61 60 97510 | |
| For measurement in generally watery media (e. g. waste water, aquariums, swimming pools) and in water-based varnishes, paints, emulsions and suspensions. Suitable for field measurements, changing temperatures and temperature-compensated measurements. Sturdy carrying case for unit and electrode including pH/Pt 1000 combination electrode (plastic body), one bag each of Knick technical buffer solutions with pH 4, 7 and 9 and replacement electrode quiver. | |
| pH set B, ZU 0511 | 61 60 97511 | |
| For measurement in generally watery media, biological media, photographic chemicals, hot alkaline solutions, media containing sulfide, corrosive acid and alkaline solutions. For extreme pH values, high temperatures, temperature-compensated and high-precision measurements. Sturdy carrying case for unit and electrode including pH/Pt 1000 combination electrode (glass body), one bag each of Knick technical buffer solutions with pH 4, 7 and 9 and replacement electrode quiver. | |
| pH set C, ZU 0512 | 61 60 97512 | |
| for puncture measurements (including in foodstuffs such as meat, fruit and milk products). Also suitable for measurement in soil samples. Sturdy carrying case for unit and electrode including combination pH puncture electrode, one bag each of Knick technical buffer solutions with pH 4, 7 and 9 and replacement electrode quiver. | |
| 

|
|