 | Chemic ALS - Via S.Francesco d'Assisi, 200 - 70018 Rutigliano (BA) - Italy - tel. (+39)080.476.10.66 - fax (+39)080.476.11.26 - info@labcatalogo.it - www.labcatalogo.it |
Main -> Measuring systems -> Temperature -> Digital thermometers |
Digital Measuring Sets PHYSICS, Schneider |
Precise and highly variable digital measuring sets PHYSICS 51, PHYSICS 300 and PHYSICS 1000
Ready to use set in a stable hard protective case including: digital measuring device PHYSICS, software PHYSICS View, temperature sensor, mains adapter 230 V, USB cable and DKD calibration certificate. Various measurement tasks and functions are achievable e.g. temperature (Pt100, thermocouples, NTC, infrared), air humidity, air flow, pressure, power, flow rate, electrical values etc. Up to 3 channels or 3 measuring points can be covered simultaneously and subject to type of probe 4 internal per function channels can be processed.
Technical data PHYSICS 51: |
Measured parameters: | Temperature, air humidity |
Measuring input: | 1 input channel |
Galvanic isolation: | Semiconductor relais (50 V) |
Channels: | 4 channels/plugs for dual probes and function channels |
Output: | 2 output channels |
1 input channel for thermocouples, NTC resistance thermometers, humidity probes etc. |
Operating air humidity: | 10 to 90 % R.H. (non condensing) |
Probe: | Immersion thermo couple NiCr-Ni Type K, acc. to DIN EN 60584 class 2 |
Measuring range: | -100 up to +800 °C |
| |
Technical data PHYSICS 300: |
Measured parameters: | mbar, Pa, lux, °C, °F, Hz, kJ/kg, %H, ppm, mA, V, min, W/m2, mS, bar, g/Kg, m/s, pH |
Measuring input: | 3 input channels for some 65 measuring units |
Galvanic isolation: | Semiconductor relais (50 V) |
Channels: | 4 channels/plugs for dual probes and function channels, 4 internal channels (e.g. balance/channel) |
Output: | 2 output channels for analog, data, trigger, relay cable, memory modules etc.) |
Resolution options: | 0.01 or 0.1 |
Measuring functions: | measuring value, zero-setting, set-point adjustment, 2-step adjustment, scaling (optional: multi-point calibration for temperature values) |
Functions: | max./min. value, average value by time, single values or meauring points |
Measuring menue free programmable (numeric or graph display) |
Internal memory: | 59 kB EEPROM (12000 values) |
Probe: | Immersion resistance thermometer Pt100 acc. to DIN EN 60751 Class A, 4-wire connection |
Measuring range: | -90 up to +350 °C |
| |
Technical data PHYSICS 1000: |
Measuring input: | 2 input channels for Pt100 temperature probes |
Measuring range: | -200 °C up to +400 °C |
Resolution: | 0.001 K / 0.01 K, non-linear calibration! |
Self calibration: | Zero point, measuring current |
Accuracy: | 0.01 % of value ±3 digits |
Temperature drift: | 0.003 %/°C |
Output: | 1 plug for USB, V24, Ethernet, Bluetooth |
Internal RAM memory: | 99 values |
Output socket: | Memory plug for 25,000 values |
Probe: | Immersion resistance thermometer Pt100 acc. to DIN EN 60751 Class A, 4-wire connection |
Measuring range: | -90 up to +350 °C |
| |
Technical data PHYSICS 51, PHYSICS 300 and PHYSICS 1000: |
Keyboard: | 7 silicone keys |
Batteries: | 3 Mignon Alkaline |
Mains adapter: | 230 V (AC) to 12 V (DC), 200 mA, galvanically isolated |
DC adapter cable: | 10 – 30 V, 0.25 A, galvanically isolated |
Operating temperature: | -10 to +60 °C |
Display illumination: | 2 LEDs, white |
Language selection: | German, English, French |
Dimensions and weight: | L 127 × W 83 × H 42 mm, 290 g |
Casing: | ABS (max. 70°C), light grey |
Degree of protection: | IP 54 |
Including DKD calibration certificate (for the measuring unit temperature) |
Probes
| Article | Order No. | |
| Immersion resistance thermometer Pt100 for PHYSICS 51 | 10 16 59954 | |
| Measuring range: -90 – +350°C | |
| Immersion resistance thermometer Pt100 for PHYSICS 300 | 10 16 59966 | |
| Measuring range: -50 – +200°C | |
| Immersion thermocouple Type K for PHYSICS 51 and 300 | 10 16 59961 | |
| Measuring range: -100 – +500°C, sensor: 1.5 dia. | |
| Immersion thermocouple Type K for PHYSICS 51 and 300 | 10 16 59963 | |
| Measuring range: -50 – +200°C | |
| Humidity psychrometer for PHYSICS 300 | 10 16 59937 | |
| Suitable for high temperatures and long-term measurements Psychrometer encoder Measuring range: 10 – 100 % r.H. at 0 – 90°C | |
| Capacitive humidity sensor for PHYSICS 51 and 300 | 10 16 59644 | |
| Measuring range: 5 – 98 % r.H. / -20 – +80°C | |
| Humidity psychrometer for PHYSICS 300 | 10 16 59638 | |
| Hand-held psychrometer Measuring range: 10 – 100 % r.H. at 0 – 60°C | |
| Humidity/temperature sensor for PHYSICS 300 | 10 16 59938 | |
| With electronic box in all-weather protective housing Measuring range: -30 – 60°C / 0 – 90 % r.H. non-condensing | |
| Room climate sensor/globe thermometer for PHYSICS 300 | 10 16 59639 | |
| Wet Bulb Globe Temperature measuring (WBGT) Measuring range: -50 – 200°C | |
| Sensor for barometric pressure for PHYSICS 300 | 10 16 59645 | |
| Measuring range: 700 – 1,050 mbar (0 – 1,050 mbar) | |
| Infrared temperature sensor for PHYSICS 300 | 10 16 59128 | |
| Measuring range: -20 – 350°C | |
| Humidity psychrometer for PHYSICS 300 | 10 16 59270 | |
| Glas version with marks of immersion depths Measuring range: -50 – +310°C, resolution 0.001°C | |
| Humidity psychrometer for PHYSICS 300 | 10 16 59265 | |
| Metal version for 100 – 250 mm immersion depths Measuring range: -90 – +410°C, resolution 0.001°C | |
Accessories
| 



|
|