The UV-Vis spectrophotometer UV mini-1240 is a compact, budget-priced system with a measuring range of 190 to 1100 nm and a spectral band width of 5 nm. With large LCD sceen indicating the on-board software for easy communication. By default, three basic operations are available: photometry, spectra registration, and quantitative analysis.
In addition to these standard measuring options, the range of applications is extended by IC cards that allow you to perform time-dependent measurements, kinetics, protein quantification, and multi-wavelength measurement (max. 6). With extensive accessories for individual use in the sample compartment to support the wide range of applications. Data is output directly via a Centronics interface to a standard printer (available as an option). Alternatively, data may be transmitted to a PC via serial interface.
Technical Data: | |
Wavelength range: | 190.0 to 1100.0 nm |
Wavelength indication: | 0.1 nm steps |
Setting of wavelength: | 0.1 nm steps (1 nm steps in Spectrum mode) |
Scanning speed: | Change of wavelength: approx. 3,800 nm/min Scan: approx. 24 to 1,400 nm/min |
Change of light source: | 3 options: - Automatic lamp change in a preselectable range between 295 nm to 364 nm in 1 nm steps (recommended: 340 nm)
- Halogen lamp only
- Deuterium lamp only
|
Measuring method: | Single-beam |
Light source: | Automatic correction and setting of the position for maximum sensitivity, 20 W halogen lamp (2,000 operating hours) Deuterium lamp (with base) |
Monochromator: | Aberration-corrected holographic grating |
Detector: | Silicium photodiode |
Spectral bandwidth: | 5 nm |
Wavelength accuracy: | ±1.0 nm |
Wavelength reproducibility: | ±0.3 nm |
Stray light: | <0.05 % (with 220.0 nm NaI, 340.0 nm NaNO2 & UV39) |
Photometric range: | 0.3 to 3.0 Abs 0.0 to 200% T |
Display: | -3.99 to 3.99 Abs -399 to 399% T |
Photometric accuracy: | ±0,005 Abs (at 1.0 Abs) NIST 930D filter ±0,003 Abs (at 0.5 Abs) |
Photometric reproducibility: | ±0,002 Abs (at 1.0 Abs) |
Drift: | < ±0,001 Abs/h (after 2 hrs. of heating) |
Deviation from base lines: | ±0,010 Abs |
Noise: | < 0.002 Abs, peak to peak < 0,0005 Abs, RMS |
Dimensions of sample compartment: | 110.0 × 230.0 × 105.0 mm (partial depth: 155.0 mm) |
Display: | 6 inch LCD (320 × 240 dot) with contrast setting |
Power supply: | 100 ∼ 120 V, 50/60 Hz, 160 VA 220 ∼ 240 V, 50/60 Hz, 160 VA |
Dimensions (W × D × H): | 416 × 379 × 247 mm |
Weight: | 11 kg |
Ambient temperature: | 15 ∼ 35°C |
Moisture: | 45 ∼ 80%, <70% at more than 30°C |