 | Chemic ALS - Via S.Francesco d'Assisi, 200 - 70018 Rutigliano (BA) - Italy - tel. (+39)080.476.10.66 - fax (+39)080.476.11.26 - info@labcatalogo.it - www.labcatalogo.it |
Main -> Volumetry -> Dosing devices -> Burettes, titrators, accessories |
Automatic Titrators, SI Analytics |
1 TitroLine® 6000
Compact, new, easy to use titrator with intelligent exchange unit and automatic recognition of unit size and reagent data. Thanks to the state-of-the-art USB and additional RS232 interfaces, connection of printer, balance and further accessories is possible at the same time. The high-contrast TFT-display allows the easy parameterization and tracking of the titration curve. The following types of titration are possible: - Titrations to pH, mV and µA endpoint (2 EP)
- Titrations to one equivalence point (pH und mV) with dynamic or linear titration addition
- Manual titrations with the controller
- Dosing tasks
- Number of methods: > 15
Typical applications for the TitroLine® 6000 comprise: - Salt content in foodstuffs (cheese, soy sauce, ketchup)
- Total acidity in wine and beverages
- SO2 in wine and beverages
- Formol number
- Degree of acidity in bread dough
- Iodine and peroxide number
- Nitrogen according to Kjeldahl
- Chloride in drinking water and other samples
- Alkalinity (p + m-value) and alkalinity
- Total hardness
- FOS / TAC
Technical data: | |
Measuring input electrode: | pH/mV-input with DIN or BNC socket |
Measuring input Dead Stop: | µA-input for double platinum electrode (socket 2 × 4 mm), pole voltage adjustable |
Measuring input Pt 1000 | Temperature sensor input for resistance thermometer Pt 1000 (socket 2 × 4 mm) |
Interfaces: | 3 × USB (2 USB-A and 1 × USB-B) 2 × RS-232-C |
Stirrer connection: | TM 235 or alternative paddle stirrer via USB-A |
Keyboard connection: | The unit is operated via the keys at the unit, the controller TZ 3880, or optionally via external PC keyboard (USB) |
Display: | 3.5″ graphic TFT display |
Exchangeable burette units: | 5, 10, 20 or 50 ml exchangeable units with unit size and reagent recognition |
Burette resolution: | 10,000 increments |
Dosing accuracy: | Systematic error 0.1 – 0.5%, random error 0.05 – 0.07% (depending on unit size) in compliance with EN ISO 8655 part 3 |
Mains supply: | 100 to 240 V, 50 / 60 Hz |
Conformity: | ISO 8655, part 6 |
CE mark: | EMC: 2004/108/EG; safety EC-Directive 2006/95 |
Technical modifications reserved. |
| Article | Order No. | |
| TitroLine® 6000 with 10 ml exchange unit, TL 6000-M1/10 | 10 27 10050 | |
| TitroLine® 6000 basic unit with magnetic stirrer TM 235 and 10 ml exchange unit WA 10, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip | |
| TitroLine® 6000 with 20 ml exchange unit, TL 6000-M1/20 | 10 27 10060 | |
| TitroLine® 6000 basic unit with magnetic stirrer TM 235 and 20 ml exchange unit WA 20, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip | |
| TitroLine® 6000 with 50 ml exchange unit, TL 6000-M1/50 | 10 27 10070 | |
| TitroLine® 6000 basic unit with magnetic stirrer TM 235 and 50 ml exchange unit WA 50, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip | |
| TitroLine® 6000 with 20 ml exchange unit and pH electrode, TL 6000-M2/20 | 10 27 10080 | |
| TitroLine® 6000 basic unit with magnetic stirrer TM 235 and 20 ml exchange unit WA 20, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip. With pH combination electrode IL-pHT-A120MF-DIN-N and buffer set. | |
2 TitroLine® 7000
Compact, new titrator with intelligent exchange unit and automatic recognition of unit size and reagent data. Automatic recognition of ID sensors by SCHOTT® Instruments. Thanks to the state-of-the-art USB and additional RS232 interfaces, connection of printer, balance and further accessories is possible at the same time. The high-contrast TFT-display allows the easy parameterization and tracking of the titration curve. The following types of titration are possible: - Titrations to pH, mV and µA endpoint (2 EP)
- Titrations to two equivalence point (pH und mV) with dynamic or linear titration addition
- pH stat titrations
- Manual titrations with the controller
- Dosing tasks
- Preparation of solutions
- Number of methods: > 50
The unit is suitable for the typical applications for the TitroLine® 6000 (see there) and additionally: - Ca-und Mg-hardness
- Acidity number (FFA) in edible oils
- Saponification number
- Hydroxy number
- Perchloric acid titrations and other non aqueous titrations
Technical data: | |
Measuring input electrode: | pH/mV-input with DIN or BNC socket with ID function for automatic electrode recognition |
Measuring input Dead Stop: | µA-input for double platinum electrode (socket 2 × 4 mm), pole voltage adjustable |
Measuring input Pt 1000: | Temperature sensor input for resistance thermometer Pt 1000 (socket 2 × 4 mm) |
Interfaces: | 3 × USB (2 USB-A and 1 × USB-B) 2 × RS-232-C |
Stirrer connection: | TM 235 or alternative paddle stirrer via USB-A |
Keyboard connection: | The unit is operated via the keys at the unit, the controller TZ 3880, or optionally via external PC keyboard (USB) |
Display: | 3.5″ graphic TFT display |
Exchangeable burette units: | 5, 10, 20 or 50 ml exchangeable units with unit size and reagent recognition |
Burette resolution: | 10,000 increments |
Dosing accuracy: | Systematic error 0.1 – 0.5%, random error 0.05 – 0.07% (depending on unit size) in compliance with EN ISO 8655 part 3 |
Mains supply: | 100 to 240 V, 50 / 60 Hz |
Conformity: | ISO 8655, part 6 |
CE mark | EMC: 2004/108/EG; safety EC-Directive 2006/95 |
Technical modifications reserved. |
| Article | Order No. | |
| TitroLine® 7000 with 10 ml exchange unit, TL 7000-M1/10 | 10 27 10140 | |
| TitroLine® 7000 basic unit with magnetic stirrer TM 235 and 10 ml exchange unit WA 10, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip | |
| TitroLine® 7000 with 20 ml exchange unit, TL 7000-M1/20 | 10 27 10150 | |
| TitroLine® 7000 basic unit with magnetic stirrer TM 235 and 20 ml exchange unit WA 20, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip | |
| TitroLine® 7000 with 50 ml exchange unit, TL 7000-M1/50 | 10 27 10160 | |
| TitroLine® 7000 basic unit with magnetic stirrer TM 235 and 50 ml exchange unit WA 50, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip | |
| TitroLine® 7000 with 20 ml exchange unit and pH electrode, TL 7000-M2/20 | 10 27 10170 | |
| TitroLine® 7000 basic unit with magnetic stirrer TM 235 and 20 ml exchange unit WA 20, incl. brown glass bottle for titration reagent, GL 45 and S 40 bottle adapter, tubes, drip tube, and titration tip. With pH combination electrode IL-pHT-A120MF-DIN-N and buffer set. | |
Accessories for TitroLine® 6000 and TitroLine® 7000
| 

|
|