 | Chemic ALS - Via S.Francesco d'Assisi, 200 - 70018 Rutigliano (BA) - Italy - tel. (+39)080.476.10.66 - fax (+39)080.476.11.26 - info@labcatalogo.it - www.labcatalogo.it |
Main -> Volumetry -> Dosing devices -> Dispensers |
Bottle-Top Dispenserr VITLAB® simplex, VITLAB |
Simple and safe handling have made this bottle-top dispenser so popular.
1 Bottle-Top Dispenser VITLAB® simplex
- Quick, easy and precise volume setting
- No dripping when gauge cap is fitted
- High-quality material (PTFE, PFA, FEP, borosilicate glass, platinum-iridium) guarantee highest chemical stability against most acids, solvents and bases
- Thanks to a directly displacing piston with PCA-seal, liquids crystallise less frequently and thus the piston does not get stuck
- Easy to disassemble for cleaning, without tools
- Completely autoclavable at 121°C
- Device turnable by 360° on the bottle
- Telescope suction tube extractable from 200 to 350 mm
- Conformity certified according to DIN 12600
- Error margin according to DIN EN ISO 8655-5
- Accuracy = ±0.5%, at nominal volume 2.5 ml = ±0.6%
- Variations coefficient = 0.1%
Included: Bottle-top dispenser, 3 PP adapter (see table), 1 telescope suction tube (200 – 350 mm), 1 installation wrench, user manual, quality certificate with test values.
| Volume ml | Graduation ml | Thread GL | Adapter | Order No. | |
| 0,25 – 2,5 | 0.05 | 32 | GL 28, 45, S 40 | 10 85 31503 | |
| 0,5 – 5,0 | 0.10 | 32 | GL 28, 45, S 40 | 10 85 31504 | |
| 1,0 – 10,0 | 0.20 | 32 | GL 28, 45, S 40 | 10 85 31505 | |
| 2,5 – 25,0 | 0.50 | 45 | GL 32, 38, S 40 | 10 85 31506 | |
| 5,0 – 50,0 | 1.00 | 45 | GL 32, 38, S 40 | 10 85 31507 | |
| 10,0 – 100,0 | 2.00 | 45 | GL 32, 38, S 40 | 10 85 31508 | |
Bottle-Top Dispenser VITLAB® simplex fix
- Fixed preset volume
- No dripping when gauge cap is fitted
- High-quality material (PTFE, PFA, FEP, borosilicate glass, platinum-iridium) guarantee highest chemical stability against most acids, solvents and bases
- Thanks to a directly displacing piston with PCA-seal, liquids crystallise less frequently and thus the piston does not get stuck
- Easy to disassemble for cleaning, without tools
- Completely autoclavable at 121°C
- Device turnable by 360° on the bottle
- Telescope suction tube extractable from 200 to 350 mm
- Conformity certified according to DIN 12600
- Error margin according to DIN EN ISO 8655-5
- Accuracy = ±0.5%, at nominal value 1.0 ml = ±0.6%
- Variations coefficient = 0.1%
Included: Bottle-top dispenser, , 3 PP adapter (see table), 1 telescope suction tube (200 – 350 mm), 1 installation wrench, user manual, quality certificate with test values
2 Bottle-Top Dispenser VITLAB® genius
- Quick, easy and precise volume setting
- Innovative back-dispensing valve permits venting in closed system - thus no reagent loss
- No dripping when gauge cap is fitted
- Can easily be recalibrated
- High-quality material (PTFE, PFA, FEP, borosilicate glass, platinum-iridium) guarantee highest chemical stability against most acids, solvents and bases
- Thanks to a directly displacing piston with PCA-seal, liquids crystallise less frequently and thus the piston does not get stuck
- Easy to disassemble for cleaning, without tools
- Completely autoclavable at 121°C
- Device turnable by 360° on the bottle
- Telescope suction tube extractable from 200 to 350 mm
- Conformity certified according to DIN 12600
- Error margins according to DIN EN ISO 8655-5
- Accuracy = ±0.5%, at nominal value 2.5 ml = ±0.6%
- Variation coefficient = 0.1%
Included: Bottle-top dispenser, 3 PP adapter (see table), 1 telescope suction tube (200 – 350 mm), 1 installation wrench, user manual, quality certificate with test values.
| Volume ml | Graduation ml | Thread GL | Adapter | Order No. | |
| 0,25 – 2,5 | 0.05 | 32 | GL 28, 45, S 40 | 10 85 35503 | |
| 0,5 – 5,0 | 0.10 | 32 | GL 28, 45, S 40 | 10 85 35504 | |
| 1,0 – 10,0 | 0.20 | 32 | GL 28, 45, S 40 | 10 85 35505 | |
| 2,5 – 25,0 | 0.50 | 45 | GL 32, 38, S 40 | 10 85 35506 | |
| 5,0 – 50,0 | 1.00 | 45 | GL 32, 38, S 40 | 10 85 35507 | |
| 10,0 – 100,0 | 2.00 | 45 | GL 32, 38, S 40 | 10 85 35508 | |
Bottle-Top Dispenser Dispenser VITLAB® HF
For dispensing hydrofluoric acid (A). With back dispensing valve and media-specific after-adjustment. Media-touching parts made of ceramics (cylinder, valve seat, ball valve) and platinum-iridium. - Quick, easy and precise volume setting
- Innovative back-dispensing valve permits venting in closed system - thus no reagent loss
- No dripping when gauge cap is fitted
- Can easily be calibrated
- Easy to disassemble for cleaning, without tools
- Completely autoclavable at 121°C
- Device turnable by 360° on the bottle
- Conformity certified according to DIN 12600
- Error margins according to DIN EN ISO 8655-5
- Accuracy = ±0.5%
- Variations coefficient = 0.1%
Included: Bottle-top dispenser, 5 PP adapter (see table), 1 telescope suction tube (125 – 240 mm), 1 installation wrench, user manual, quality certificate with test values.
| Volume ml | Graduation ml | Thread GL | Adapter | Order No. | |
| 1,0 – 10,0 | 0.20 | 45 | GL 25, 28 32, 38, S 40 | 10 85 36515 | |
Accessories
| Article | Order No. | |
| Drying tube (complete, without filling) | 10 85 31095 | |
| 

|
|