Chemic ALS - Via S.Francesco d'Assisi, 200 - 70018 Rutigliano (BA) - Italy - tel. (+39)080.476.10.66 - fax (+39)080.476.11.26 - info@labcatalogo.it - www.labcatalogo.it
Main -> Volumetry -> Dosing devices -> Dispensers
Bottle-Top Dispenserr VITLAB® simplex, VITLAB

Simple and safe handling have made this bottle-top dispenser so popular.

1 Bottle-Top Dispenser VITLAB® simplex

  • Quick, easy and precise volume setting
  • No dripping when gauge cap is fitted
  • High-quality material (PTFE, PFA, FEP, borosilicate glass, platinum-iridium) guarantee highest chemical stability against most acids, solvents and bases
  • Thanks to a directly displacing piston with PCA-seal, liquids crystallise less frequently and thus the piston does not get stuck
  • Easy to disassemble for cleaning, without tools
  • Completely autoclavable at 121°C
  • Device turnable by 360° on the bottle
  • Telescope suction tube extractable from 200 to 350 mm
  • Conformity certified according to DIN 12600
  • Error margin according to DIN EN ISO 8655-5
  • Accuracy = ±0.5%, at nominal volume 2.5 ml = ±0.6%
  • Variations coefficient = 0.1%

Included:
Bottle-top dispenser, 3 PP adapter (see table), 1 telescope suction tube (200 – 350 mm), 1 installation wrench, user manual, quality certificate with test values.

Volume
ml
Graduation
ml
Thread GLAdapterOrder No.
0,25 – 2,50.0532GL 28, 45, S 4010 85 31503
0,5 – 5,00.1032GL 28, 45, S 4010 85 31504
1,0 – 10,00.2032GL 28, 45, S 4010 85 31505
2,5 – 25,00.5045GL 32, 38, S 4010 85 31506
5,0 – 50,01.0045GL 32, 38, S 4010 85 31507
10,0 – 100,02.0045GL 32, 38, S 4010 85 31508


Bottle-Top Dispenser VITLAB® simplex fix

  • Fixed preset volume
  • No dripping when gauge cap is fitted
  • High-quality material (PTFE, PFA, FEP, borosilicate glass, platinum-iridium) guarantee highest chemical stability against most acids, solvents and bases
  • Thanks to a directly displacing piston with PCA-seal, liquids crystallise less frequently and thus the piston does not get stuck
  • Easy to disassemble for cleaning, without tools
  • Completely autoclavable at 121°C
  • Device turnable by 360° on the bottle
  • Telescope suction tube extractable from 200 to 350 mm
  • Conformity certified according to DIN 12600
  • Error margin according to DIN EN ISO 8655-5
  • Accuracy = ±0.5%, at nominal value 1.0 ml = ±0.6%
  • Variations coefficient = 0.1%

Included:
Bottle-top dispenser, , 3 PP adapter (see table), 1 telescope suction tube (200 – 350 mm), 1 installation wrench, user manual, quality certificate with test values

Volume
ml
Thread GLAdapterOrder No.
1,032GL 28, 45, S 4010 85 32503
5,032GL 28, 45, S 4010 85 32504
10,032GL 28, 45, S 4010 85 32505


2 Bottle-Top Dispenser VITLAB® genius

  • Quick, easy and precise volume setting
  • Innovative back-dispensing valve permits venting in closed system - thus no reagent loss
  • No dripping when gauge cap is fitted
  • Can easily be recalibrated
  • High-quality material (PTFE, PFA, FEP, borosilicate glass, platinum-iridium) guarantee highest chemical stability against most acids, solvents and bases
  • Thanks to a directly displacing piston with PCA-seal, liquids crystallise less frequently and thus the piston does not get stuck
  • Easy to disassemble for cleaning, without tools
  • Completely autoclavable at 121°C
  • Device turnable by 360° on the bottle
  • Telescope suction tube extractable from 200 to 350 mm
  • Conformity certified according to DIN 12600
  • Error margins according to DIN EN ISO 8655-5
  • Accuracy = ±0.5%, at nominal value 2.5 ml = ±0.6%
  • Variation coefficient = 0.1%

Included:
Bottle-top dispenser, 3 PP adapter (see table), 1 telescope suction tube (200 – 350 mm), 1 installation wrench, user manual, quality certificate with test values.

Volume
ml
Graduation
ml
Thread GLAdapterOrder No.
0,25 – 2,50.0532GL 28, 45, S 4010 85 35503
0,5 – 5,00.1032GL 28, 45, S 4010 85 35504
1,0 – 10,00.2032GL 28, 45, S 4010 85 35505
2,5 – 25,00.5045GL 32, 38, S 4010 85 35506
5,0 – 50,01.0045GL 32, 38, S 4010 85 35507
10,0 – 100,02.0045GL 32, 38, S 4010 85 35508


Bottle-Top Dispenser Dispenser VITLAB® HF

For dispensing hydrofluoric acid (A). With back dispensing valve and media-specific after-adjustment. Media-touching parts made of ceramics (cylinder, valve seat, ball valve) and platinum-iridium.

  • Quick, easy and precise volume setting
  • Innovative back-dispensing valve permits venting in closed system - thus no reagent loss
  • No dripping when gauge cap is fitted
  • Can easily be calibrated
  • Easy to disassemble for cleaning, without tools
  • Completely autoclavable at 121°C
  • Device turnable by 360° on the bottle
  • Conformity certified according to DIN 12600
  • Error margins according to DIN EN ISO 8655-5
  • Accuracy = ±0.5%
  • Variations coefficient = 0.1%

Included:
Bottle-top dispenser, 5 PP adapter (see table), 1 telescope suction tube (125 – 240 mm), 1 installation wrench, user manual, quality certificate with test values.

Volume
ml
Graduation
ml
Thread GLAdapterOrder No.
1,0 – 10,00.2045GL 25, 28 32, 38, S 4010 85 36515


Accessories
ArticleOrder No.
Drying tube (complete, without filling)10 85 31095